Home » Merken » Shaker Solutions

Shaker Solutions

j.j. bos b.v. provides service for all the Electro-Dynamic Shakers manufacturers and is specialised in Tira for the BENELUX market.

With a great range of customers all over the BENELUX j.j. bos b.v. gained knowledge directly form the field.

This experience we take with us to every new challenge our customer are into and together keep everything running and helping making decisions for service , repair and replacing.

 

Shaker explained

Basics of vibration testing and technology

The Shaker (also called vibration exciter)

The mode of function of a shaker corresponds to that of a loudspeaker. The vibration movement is generated by the interaction of electric current passing through the plunger coil and a magnetic field. The force used to accelerate the moving element comprised of a ribbed body and the wrapped plunger coil is proportional to the coil current, the magnetic flux density, and the length of conductor in the magnetic field. The vibration level of shaker can therefore be controlled by electric current intensity.

Graph 1 shows the sectional view of a shaker. In case of small shakers, the magnetic field is generated by means of permanent magnets and, in case of larger, base-mounted ones, by means of electromagnets. The maximum achievable acceleration is dependent on current intensity and total effective mass to be moved. At low frequencies, however, the limits of vibration velocity and displacement (travel) are reached earlier than those of acceleration.

Graph 2

shows the acceleration as a function frequency in double-logarithmic (log-log) scale. The displacement limit is represented as a straight line with a slope of 12 dB/octave. A vibration velocity limit is often encountered on larger shakers, depending on the warm-up of springs and the maximum output voltage of power amplifier. This vibration velocity limit is represented as a straight line with a slope of 6 dB/octave. The upper frequency limit depends on the self-resonant frequency of moving element.


The Control

A defined vibration amplitude of armature is required for vibration testing. The frequency response curve, however, is not flat but shows resonance peaks. Other resonances will be produced by the specimen. That is why the gain must be varied with the frequency run, comparing the actual vibration value of armature with specimen to a specified setpoint value. The vibration table control mainly consists of frequency generator, vibration meter and control amplifier (Graph 3).


The Power Amplifier

The frequency response curve of a shaker driven by a constant current can be broken down into three sections. The first two ones represent the spring-mass system of moving element and its suspension with a self-resonant frequency of 20 Hz. In the third section, axial resonances in the moving element will occur, thus defining the upper frequency limit of a shaker. This limit is typically over 3 kHz for large shakers.

The frequency response curve for a shaker with constant voltage input can also be broken down into three sections. The lower self-resonant frequency, however, appears considerably damped, providing an easier control of vibration level. The constant driving voltage is generated by power amplifiers of low impedance output and normally preferred for almost all vibration tests. In the medium range, however, current control will partially be more advantageous, primarily in such cases where the shaker is used as force generator or run in non-feedback control mode. Unlike voltage control, this requires a high impedance output of amplifiers which will often have selectable impedance outputs

.

Laatste nieuws
The Vac Techniche Plasma Cleaner / Asher M2V03VT

The M2V03VT from VacTechniche is a compact desktop reaction chamber that allows you to clean materials and treat surfaces using plasma. The […]

Lees meer
De Vac Techniche Plasma Cleaner / Asher M2V03VT

De M2V03VT van Vac Techniche Ltd. is een compacte desktop-reactiekamer waarmee u materialen reinigt en oppervlakten behandelt met plasma. Het geïoniseerde gas […]

Lees meer
VITO selects TSI for Actris UFP measurements

Also VITO in Flanders selected TSI for two mobile (Counting & Sizing) measurement solutions for ultrafine particles as small as 10 nm. […]

Lees meer
Ook het VITO kiest voor TSI UFP meetoplossing

Voor 2 mobiele (Counting & Sizing) meetoplossingen voor ultrafijn stof vanaf 10 nm. heeft ook het VITO in Vlaanderen in het kader […]

Lees meer
Het uitkiezen van een Vac Coat coater op kenmerken

Het onderstaande stroomdiagram is erg handig voor het uitkiezen van de juiste coater. Klik op de modelnaam van de coater en u […]

Lees meer
To choose a Vac Coat coater by feature

The flowchart below is very useful for selecting the right coater by feature. Click on the model name of the coater to […]

Lees meer
De Vac Coat Pulsed Laser Deposition- en Thermisch Verdampingssysteem – PLD-T

Het PLD-T-systeem is een vacuüm-systeem voor dunnefilmdepositie, waarmee verschillende materialen kunnen worden afgezet via zowel Pulsed Laser Deposition (PLD) als  thermische verdamping […]

Lees meer
The Vac Coat Pulsed Laser Deposition and Thermal Evaporator System – PLD-T

The versatile Pulsed Laser Deposition and Thermal Evaporator System – PLD-T is a high vacuum thin film deposition system enables to deposit […]

Lees meer
De Vac Coat Sputter Coater en Thermische Verdampingsunit – DST3-T

De DST3-T is een multi-vacuüm-coatingsysteem met drie targets en een turbomoleculaire pomp dat een thermische verdamper en een sputtercoater combineert in één […]

Lees meer
The Vac Coat Sputter Coater and Thermal Evaporator – DST3-T

The DST3-T is a triple-target turbomolecular-pumped multi-vacuum-coating system that combines a thermal evaporator and a sputter coater into a single compact desktop system. The high-vacuum […]

Lees meer

Informatie aanvragen?

"*" geeft vereiste velden aan